University of Navarra Implements Wyatt Technology Dynamic Light Scattering for Critical Micellization of Polymeric Systems with Temperature

SANTA BARBARA, CALIFORNIA — Wyatt Technology Corporation, the world leader in absolute macromolecular characterization instrumentation and software, has been chosen by the University of Navarra for its instruments to characterize phase transitions and structures in micellar

polymeric systems. Wyatt Technology’s dynamic light scattering instrument, the DynaPro, facilitated the detection of aggregation in early stages of micellization of pluronic polymeric surfactant due to temperature effects, pH, salinity concentration and composition.

The DynaPro from Wyatt Technology offers scientists the ability to measure small volumes of dilute protein samples. These novel dynamic light scattering (DLS) instruments have been indispensable tools for scientists examining protein structure. One of the key strengths of DLS technology is

its capability of detecting aggregation early due to temperature effects, pH, salinity concentration or composition. The unique temperature control capability of the DynaPro allows for accelerated stability, thermal melting and temperature studies of multiple samples to be performed in parallel and

with improved response time. The DynaPro achieves simultaneous and rapid evaluation of the total scattering intensity and the hydrodynamic radii spectrum in micellar polymeric systems with temperature in a non-invasive fashion.

For the application at the University of Navarra, the system was used for the micellization of a Pluronic polymeric surfactant with temperature. These amphiphiles are low molecular weight linear triblock copolymers of polyethylene oxide (PEO) and polypropylene oxide (PPO), with structures

PEO-PPO-PEO, in which the hydrophilic character is controlled according to the PEO block length. Pluronic F108 was chosen which was a central block of 52 PO monomers and PEO wings of 131 EO.

The results demonstrate that, at a low temperature, the polymeric surfactant exists in monomer form. The onset of micellization can be easily perceived both in the intensity and in the hydrodynamic radius obtained by the cumulants method of Wyatt Technology’s DYNAMICS software. The regularization

analysis of DYNAMICS provides the size spectrum of the sample and reveals a new peak corresponding to the micelles. A copy of the new application note, entitled “Critical Micellization Temperature (CMT) of Block Copolymers of PEO and PPO”, is available to download free-of-charge via www.wyatt.com.

For more information on Wyatt Technology’s DynaPro instrument and its DYNAMICS data collection and analysis software or to obtain a copy of this application note, please visit www.wyatt.com or email [email protected].

About Wyatt

Based in Santa Barbara, California, Wyatt Technology is the world’s leading provider of instruments for absolute macromolecular characterization. With over 40 years’ experience developing multi-angle light scattering detectors, working with customers in the biotechnology, chemical, petrochemical,

pharmaceutical, academic and government arenas, Wyatt prides itself on its entrepreneurial spirit, and the uniqueness of its offerings. The Company’s groundbreaking technology and uncompromising levels of customer care make Wyatt the global hallmark in its field. For more information, please visit

www.wyatt.com

< | >